Tugas Akhir
Analisa beban pendingin pada gedung KH-IPSB3 dengan metoda cooling load temperatur difference
ANALISA KEBUTUHAN BABAN PENDINGIN DI GEDUNG KHIPSB3 DENGAN METODE COOLING LOAD TEMPERATURE DIFERANCE.Telah dilakukan Analisa dan perhitungan beban pendingin di Gedung Kanal Hubung Instalasi Penyimpanan Bahan Bakar Nuklir Bekas (KHIPSB3). Analisa dilakukan menggunakan perhitungan dengan metoda Cooling Load Temperature Diferance(CLTD). Gedung KH-IPSB3 merupakan instalasi nuklir yang ada di Pusat Teknologi Limbah Radioaktif Badan Tenaga Nuklir Nasional (PTLR-BATAN). Sebagai tempat penyimpanan bahan bakar nuklir bekas (BBNB) dibutuhkan pendinginan gedung yang memadai, saat ini terjadi kegagalan fungsi pendinginan gedung di KH-IPSB3 dengan tidak tercapainya pendinginan yang disyaratkan yaitu 250C +10C di beberapa ruangan terutama di kanal dan ruang purifikasi. Untuk memperbaiki kegagalan fungsi pendingin udara tersebut dilakukan Analisa dengan menghitung Beban pendingin di KH-IPSB3 yang kemudian dibandingkan dengan kapasitas pendinginan yang dibangkitkan oleh mesin pending. Pada perhitungan didapatkan besarnya beban pendingin sebesar 449 kW. Pada kondisi maksimal pendinginan dilakukan oleh 4 unit kompresor chiller dengan total kapasitas pendingin 422 kW, sehingga pada Gedung KH-IPSB3 terdapat kekurangan suplai pendinginan udara sebesar 27 kW. rnKata Kunci: Pendingin udara KH-IPSB3, Beban pendingin KH-IPSB3 rnrnABSTRACT rn rn COOLING LOADANALYSISIN TC ISFSF BUILDING WITH COOLING LOAD TEMPERATURE DIFFERENCE METHOD. Analysis of cooling load on the TC ISFSF Building have been done. Analysis is done by calculating the cooling load using CLTD method.TC ISFSF Building is an existing facility at the Center for Radioactive Waste Technology (CRWT-BATAN). As storage for nuclear spent fuel, TC-ISFSF requires the best performance of air conditioning system to maintenance air temperature within the 240C + 10C limit. at this time the air conditioning system is not good because the air conditioning equipment can not maintain the temperature inside the building as required especially in the tunnel and water treatment room. To overcome this problem has been done the calculation of cooling load at TC ISFSF building and get value of cooling load equal to 449 kW. TC ISFSF has 4 chiller compressor to cover cooling load inside building with each compressor can supply 105,5 kW so total of cooling load covered with 4 unit compressor are 422 kW witch mean having a deficit of cooling media equal to 27 kW to cover the cooling load of TC ISFSF building. rn rnKey words: Cooling load on TC-ISFSF, Air cooled on TC-ISFSF
S18-0197 | 10/TA/M/18 543.27.5(043) BUD a | Perpustakaan Poltek Nuklir | Tersedia |
Tidak tersedia versi lain