Tugas Akhir
Rancang bangun alat uji kelurusan berkas sinar-x medik radiografi umum
RANCANG BANGUN ALAT UJI KELURUSAN BERKAS SINAR-X MEDIK RADIOGRAFI UMUM. Pemanfaatan PesawatANALISIS PENUAAN BATANG KENDALI PENGAMAN (SAFETY CONTROL ROD) REAKTOR KARTINI BERBASIS MCNPX sinar-X harus memenuhi persyaratan keselamatan radiasi dan memberikan informasi diagnosis sehingga diperlukan uji fuANALISIS PENUAAN BATANG KENDALI PENGAMAN (SAFETY CONTROL ROD) REAKTOR KARTINI BERBASIS MCNPXngsi berupa uji kelurusan berkas sinar-X untuk memastikan bahwa datangnya pancaran sinar dari X-Ray tube sejajar dan tidak terjadi pergeseran sudut dengan tempat terjadinya gangguan pada tubuh pasien, sehingga pada pemeriksaan pasien akan presisi dan akurat. rnTelah dibuat alat untuk menguji kelurusan berkas sinar-X berupa Beam Alignment Test Tool dari bahan akrilik, memiliki titik pusat berupa bola baja dari bahan timbal (Pb) dan Collimator Test Tool dari bahan kuningan. Alat uji yang dihasilkan berupa Beam Alignment Test Tool berbentuk tabung dengan dimensi tinggi 145 mm dan diameter 60 mm. Collimator Test Tool berbentuk segi empat dengan dimensi 250×200 mm. Pengujian alat dilakukan dengan verifikasi pengukuran oleh pihak ketiga dan pengujian radiografi dengan pesawat sinar-X agar terlihat citra pada Film.rnDidapatkan hasil bahwa telah dibuat alat uji kelurusan berkas sinar-X yaitu Beam Alignment Test Tool yang dapat menghasilkan citra pada film, memiliki bentuk tabung dengan tinggi 145 mm dan diameter 60 mm. Collimator Test Tool berbentuk segi empat dengan dimensi 250×200 mm tebal 1 mm. Dengan alat uji yang dibuat dapat digunakan pada minimal kV 50 sudah tampak citra di film.rnrnKata Kunci : Pesawat sinar-X, Radiologi Medik, Berkas sinar-X, Beam Alignment Test ToolrnrnABSTRACTrnrnDESIGN BEAM ALIGNMENT TEST TOOL FOR X-RAY MEDIC GENERAL RADIOGRAPHY. The utilization of the x-Ray machine have to eligible a requirement for radiation safety and provide diagnosis information that need a compliance testing like Beam Alignment Test of X-Ray beam to ensure that the arrival of X-Ray beam from the X-Ray tube are parallel and does not shift the angle where interference with the patient’s body, so that the examination of the patient will be precise and accurate.rnIt made a tool for examined beam alignment X-Ray from acrylic as Beam Alignment Test Tool, steel balls as centre point of the Beam Alignment Test Tool in the form of lead and brass as Collimator Test Tool. The result is equipment test such as Beam Alignment Test Tool shaped is cylinder acrylic with dimensions of 145 mm height and 60 mm diameter. Collimator Test Tool shaped is rectangular with dimensions of 250x200 mm. Tools testing conducted with measurement verification by the third Agency and radiographic testing with X-rays machine to look at the image of the film. As the results is it made a tool for examined beam alignment X-ray from acrylic as Beam Alignment Test Tool, steel balls as centre point of the Beam Alignment Test Tool in the form of lead and brass as Collimator Test Tool. The result is equipment test such as Beam Alignment Test Tool shaped is cylinder acrylic with dimensions of 145 mm height and 60 mm diameter. Collimator Test Tool shaped is rectangular with dimensions of 250x200 mm. With equipment test made in kV 50 image of the film are already visible. Keywords : X-Ray machine, Medical Radiology, X-Ray Beam, Beam Alignment Test Tool
S16-0279 | 23/TA/M/16 537.531(043) AND r | Perpustakaan Poltek Nuklir | Tersedia |
Tidak tersedia versi lain