Tugas Akhir
Rancang bangun panel simulasi untuk pengujian gangguan generator 3 fasa
Merupakan hasil rekayasa dan pengembangan untuk melengkapi modul praktikum Perlengkapann Sistem Tenaga di Laboratortium Listrik Arus Kuat STTN-BATAN Yogyakarta. Panel dirancang untuk melakukan simulasi agar lebih mudah memahami dan mempelajari jenis gangguan Generator 3 fasa . Panel dilengkapi sekering sebagai pengaman generator, tahanan geser (Rheostat) untuk membatasi / menahan besarnya arus gangguan yang terjadi saat simulasi gangguan generator 3 fasa. Sehingga arus gangguan yang terjadi masih dalam batas aman arus nominal Generator dari ELWE Jerman. Panel dilengkapi sistem grounding yang dihubungkan melalui kabel ke tanah.dengan resistansi sebesar 0 ohm. Metode simulasi merupakan cara yang tepat dan aman untuk mempelajari sistem gangguan pada generator 3 fasa, dibandingkan melakukan penelitian menggunakan generator berdaya besar yang beresiko tinggi terhadap keselamatan generator atau si peneliti itu sendiri. Dengan metoda simulasi dapat dibuktikan dan diketahui besarnya arus gangguan serta penurunan voltase (tegangan) yang terjadi saat gangguan. Hasil simulasi pada generator 3 fasa besarnya arus gangguan sebesar 59,3 mA, hasil teori sebesar 65 mA. Voltase hasil simulasi 210 volt dari tegangan awal 220 volt, hasil teori 221,6 volt dari tegangan awal 223 volt. Jadi dengan simulasi akan mempermudah dalam membuktikan kebenaran hasil teori.
It is the creative and development product to complete the model of Equipment for power system for practice in the Electricity Laboratory for High-Voltage Current of STTN-BATAN Yogyakarta. The panel is designed to help doing simulation in order to get the easier understanding and learning of the types of 3-phase generator disruption. The panel is equipped with a fuse as generator security, shift resistance (Rheostat) to restrict/restrain the amount of disruption current occurring is still on the secure limit of Generator nominal current from ELWE German. The panel is equipped grounding system connected through cable to ground with resistance 0 ohm. Simulation method is an accurate and safe way to learn the disruption system on the 3-phase generator compared to the way to conduct the research using high-powered generator which is at high risk for the safety of generator or the researcher himself/herself. With simulation method the amount of disruption current can be proved and known as well as the voltage discharge occurring at the times of disruption. The result of simulation on the 3-phase generator the amount of disruption current is 59,3 mA, the result of theoretical amount is 63 mA. The voltage of simulation result is 210 volt from the initial voltage of 220 volt, the result of theoretical is 221,6 volt from the initial voltage of 223 volt. Thus, simulation will make easier in proving the correctness of theoretical result
S05-2150 | 3/TA/M/5 621.313:69.022-43 SUD r | Perpustakaan Poltek Nuklir | Tersedia |
Tidak tersedia versi lain